· by Michael Blair, Nashville's Windows & Doors
Most of what keeps water out of a doorway is out of sight by the time the door swings. The threshold covers the bottom of the opening, the trim covers the sides, and nobody looks again until the subfloor just inside the door goes soft. On an entry door replacement, the bottom of the opening gets more of our attention than any other part of the job. This is what goes there, what the code asks for, and where two well-known door makers handle it differently.
Does an exterior door need flashing?
Yes. The residential code requires approved, corrosion-resistant flashing at exterior window and door openings, lapped in shingle fashion so each piece sheds water onto the one below it. That is Section R703.4 of the 2024 International Residential Code as Metro adopted it, on UpCodes, which also names the standards the materials have to meet: AAMA 711 for self-adhered flashing tape, AAMA 714 for fluid-applied membranes and AAMA 712 for mechanically attached flexible flashing.
The next section, R703.4.1, says how. Flashing at a door has to carry water out to the face of the wall finish, or to a listed water-resistive barrier, so it can drain; the gap around the frame is air sealed on the inside; and the door maker’s installation and flashing instructions come first. Only where the maker provides no flashing instructions or details does the code itself call for pan flashing at the sill, sealed or sloped to send water out, with flashing or protection at the head and sides as well.
In Davidson County, Metro Codes’ adopted codes list names the 2024 International Residential Code, and Metro’s announcement of the 2024 code adoption applies it to applications submitted after July 16, 2025. The State Fire Marshal’s list of adopted codes shows the 2018 edition statewide, so outside Metro, the town’s building department can tell you which edition it works from.
What goes under an exterior door threshold?
Flashing that sheds water outward, a level and fully supported sill, sealant, and on many installations a sill pan. Therma-Tru’s guide to installing a door makes the sill pan its own step, third after checking the door unit and preparing the opening, and says its sill-pan kit and flexible flashing help keep the opening watertight and may be required by building codes in some areas.
Pella treats it differently. Its entry door full frame replacement installation booklet calls the sill pan optional and gives it a page of its own at the back. The main steps flash the sill with overlapping strips of flashing tape, the first run out past the exterior edge and up each jamb, then set an aluminum sill support or wood blocking flush with the opening sill. When the pan is used, it is cut to the rough opening width plus 2 inches so each end can be bent up an inch, slid in until its exterior lip is flush with the outside of the opening, and taped in with each strip overlapping the one before by an inch.
So on a Pella door, skipping the pan follows the maker’s instructions, and under R703.4.1 that satisfies the code. We use one on our replacements anyway. A pan is a tray with a back and ends turned up, so water that gets past the threshold, the corner seal pads or a bead of sealant lands in it and runs back out rather than into the subfloor. Pella’s own booklet begins by saying that all construction must anticipate some water infiltration, and the pan is where we plan for it.
How do you check that a new door is sealed at the bottom?
With a dollar bill. Step 8 of Therma-Tru’s sequence is to adjust the sill, where the sill is adjustable, until the fit is snug: close the door on a dollar bill and it should only barely pull out from between the door bottom and the sill. The next step is to check, or install, the corner seal pads where the door meets the frame at the bottom.
The test only works if the frame went in square. Therma-Tru shims the jamb at the hinge locations first, then adjusts and fastens the lock side, then completes the jamb fastening. Pella’s booklet sizes the new unit 1/2 to 3/4 inch narrower and 3/8 to 1/2 inch shorter than the opening, and that clearance is where the shims and sealant go.
A door that passes the test on install day can still drift over the years. Our post on fixing a drafty exterior door covers the weatherstripping and adjustments that bring it back.
The head and sides of the opening
The top of the opening gets the same care as the bottom. Pella’s booklet sets the head flashing over beads of sealant, fastens it with roofing nails or corrosion-resistant pan-head screws no more than 12 inches apart, and states that the flashing must slope to the exterior. It also says its instructions are for wall systems designed to manage water.
Where the new door meets siding, brick or trim, the trim and flashing work around the outside has to tie in with the flashing at the opening. If the door itself is still undecided, our comparison of steel, fiberglass and wood entry doors is the place to start. For a door replacement in Mt. Juliet, Nashville or nearby, tell us about the door and the opening and we will price it in writing.
Sources
- 2024 International Residential Code as adopted by Metro Nashville, Chapter 7, R703.4 and R703.4.1 (UpCodes’ copy) — Flashing required at door openings, lapped shingle fashion; AAMA 711, 712 and 714; the maker’s instructions first, pan flashing at the sill where none are given
- Therma-Tru Project Center, How to install a door — Installation steps; the sill-pan kit and flexible flashing may be required by code in some areas; shims at the hinges; the dollar bill test
- Pella, Entry Door Full Frame Replacement, Block Frame installation booklet (2021) — Optional sill pan instructions; sill flashing tape; head flashing fastened at 12 inches maximum and sloped to the exterior; unit sizing against the opening; construction must anticipate water infiltration
- Metro Nashville Codes, Adopted Codes List — Metro’s adoption of the 2024 International Residential Code
- Metro Nashville Codes, Metro Adopts 2024 International Building Codes — Applies to applications submitted after July 16, 2025
- Tennessee State Fire Marshal’s Office, Currently Adopted Codes — The statewide adoption lists the 2018 International Residential Code
FAQ
What Goes Under a New Exterior Door — questions
What is a sill pan for an exterior door?
A sill pan is a formed tray set under the door’s sill, with its back and ends turned up, so water that gets past the threshold or its seals is caught and sent back outside instead of into the subfloor. It rests on the bottom of the rough opening and is lapped into the flashing tape around it.
Do exterior doors need a sill pan?
The code requires flashing at every exterior door and defers to the door maker’s flashing instructions; it calls for pan flashing at the sill only where the maker gives none. Therma-Tru says a pan may be required by code in some areas, Pella calls it optional, and we install one on our replacements.
How do you flash an exterior door?
From the bottom up, lapped so each piece sheds onto the one below: flashing tape across the sill and up the jambs, or a sill pan taped in, then the sides, then head flashing over sealant, sloped outward. Self-adhered tape has to meet AAMA 711 under the code, and the door maker’s instructions set the details.
Why does water leak under my front door?
We start where the door makers put the seal: whether an adjustable sill is snug enough to pass the dollar bill test, whether the corner seal pads are in place, and whether anything under the sill sends water back out. With no flashing or pan at the sill, nothing stops water that gets past the threshold.
How do you install an exterior door?
Therma-Tru’s sequence is: check the door unit, prepare and flash the opening, install the sill pan, set the unit, shim at the hinges, fasten the lock side and the rest of the jamb, adjust the sill and run the dollar bill test, check the corner seal pads, then weatherproof and finish. Each maker’s instructions govern its own door.